- Allow the WAN link to also carry LANs when the uplink is PPPoE on a
VLAN with IPv6 off; only the PPP device counts as an uplink then, so
LAN traffic can never match WAN rules.
- Add router.rollback: router-arm / router-confirm / router-rollback
plus `nix run .#deploy`, a commit-confirm deployment flow.
- Wait for the LAN devices instead of the uplink in networkd
wait-online, so an unplugged uplink cannot block boot or activation.
- Add examples/desktop (single NIC, PPPoE on VLAN 1001) as
nixosConfigurations.example, built as a flake check.
Covered by the onestick and rollback VM tests and new assertion cases.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
LANs can sit on an 802.1Q VLAN (`vlan` on a trunk `interface`); networkd
creates the device and brings the trunk up. LANs belong to a named `zone`
(default: their own name). Traffic inside a zone is forwarded freely, traffic
between zones is denied unless a `router.firewall.rules` entry allows it
(protocol, ports, optional destination inside the target zone).
Internet access is now opt-in per LAN (`internet`, default false), replacing
the previous allow-out default. Assertions reject unknown zones, bad
destinations, duplicate devices, over-long device names and a WAN trunk.
Kea subnet IDs now come from the network address so adding LANs does not
renumber them and orphan persistent leases.
Tests: a five-VM `vlans` check (untagged + two VLANs, shared zone, one-way
rules, per-host destination restriction), new assertion cases, parseNet unit
tests, and shared test tooling in tests/common.nix.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
IPv6: router.wan.ipv6.enable mirrors the existing uplink config (DHCPv6 with
WithoutRA=solicit, delegated prefix). The ISP delegates a single /64, so
exactly one LAN may claim it via router.lans.<name>.ipv6.pd (asserted); other
LANs stay IPv4-only. SLAAC only, no NAT66.
PPPoE: router.wan.ipv4.type = "pppoe" runs pppd on an optional VLAN of the
uplink, with the password read from a file at service start (never the Nix
store). NAT, forwarding and MSS clamping (MTU 1492) use the derived PPP
device; native IPv6 stays on the untagged link.
Tests: basic.nix is parameterised by uplink type; the pppoe variant uses a
fake ISP with pppoe-server (VLAN 7, CHAP). Both variants cover IPv6 PD, SLAAC,
routing without NAT and WAN-deny. Assertion tests gain PD/PPPoE cases and a
full-system evaluation step.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
router.* schema (wan, lans, dns.forwarders) compiled to systemd-networkd,
a generated nftables ruleset with NAT, Kea DHCPv4 and Unbound, plus build-time
assertions against lock-out and interface conflicts.
tests/basic.nix is a three-node VM test (upstream/router/client) covering WAN
DHCP, LAN DHCP and DNS, NAT, WAN-deny and LAN SSH/ping. `nix run .#lab` boots
the same topology in tmux with one console pane per VM and the driver REPL.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>